BASES![]() 209 DUAL MOUNT BASE A CAST BASE THREADED FOR MOUNTING ON HORIZONTAL OR VERTICAL SURFACES USING SCREWS, 1/4 " BOLTS, 1/4" DRIVE- IN ANCHORS, OR AN ADHESIVE. BOLT TENSION CAP CAN BE TURNED SO CABLES CAN RUN HORIZONTAL OR VERTICAL. FURNISHED FOR AIR TERMINAL SIZES 3/8" AND 1/2". SPECIFY WHEN ORDERING. UL LISTED A209 ALUMINUM ![]() 210 TOP MOUNT BASE A CAST BASE THREADED FOR MOUNTING ON HORIZONTAL SURFACES USING SCREWS, 1/4 " BOLTS, 1/4 " DRIVE- IN ANCHORS, OR AN ADHESIVE. BOLT TENSION CAP CAN BE TURNED SO CABLES CAN RUN HORIZONTAL OR VERTICAL. FURNISHED FOR ALL AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A210 ALUMINUM ![]() 211 SIDE MOUNT BASE A CAST BASE THREADED FOR MOUNTING ON VERTICAL SURFACES USING SCREWS, 1/4 " BOLTS, OR 1/4 " DRIVE- IN ANCHORS. BOLT TENSION CAP CAN BE TURNED SO CABLES CAN RUN HORIZONTAL OR VERTICAL. FURNISHED FOR ALL AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A211 ALUMINUM ![]() 216 UNIVERSAL SWIVEL BASE THIS IS THE MOST UNIVERSAL BASE IN THE INDUSTRY. THE SWIVEL ADAPTOR ALLOWS THE AIR TERMINAL TO LEVEL UNDER MOST CONDITIONS. IT CAN BE SECURED WITH SCREWS, NAILS, 1/4" BOLTS, 1/4" DRIVE- IN ANCHORS, OR AN ADHESIVE. BOLT TENSION CAP CAN BE TURNED SO THE CABLE CAN RUN HORIZONTAL OR VERTICAL. PERFECT FOR SKYLIGHTS, DOMED OR GENTLY SLOPING ROOFS, OR ANY UNEVEN SURFACE. FURNISHED FOR ALL AIR TERMINALS - 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A216 ALUMINUM ![]() 218 OFFSET BASE A CAST BASE WITH A 2" OFFSET TO CLEAR AN OVERHANG WHEN MOUNTED ON A VERTICAL SURFACE USING SCREWS, 1/4 " BOLTS, OR 1/4 " DRIVE- IN ANCHORS. BOLT TENSION CAP CAN BE TURNED SO CABLES CAN RUN HORIZONTAL OR VERTICAL. FURNISHED FOR ALL AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A218 ALUMINUM ![]() 220 ADHESIVE BASE THIS BASE HAS BOLT TENSION CABLE CLAMPING AND CAN BE USED ON ANY SURFACE WITH AN ADHESIVE. FURNISHED FOR ALL AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A220 ALUMINUM ![]() 222 SIDE MOUNT BASE THIS CAST BASE HAS BOLT TENSION CABLE CLAMPING AND CAN BE MOUNTED VERTICALLY WITH SCREWS, 1/4 " BOLTS, OR 1/4 " DRIVE- IN ANCHORS. FURNISHED FOR AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A222 ALUMINUM ![]() 224 TOP MOUNT BASE THIS CAST BASE CAN BE MOUNTED HORIZONTALLY WITH SCREWS, 1/4 " BOLTS, OR 1/4" DRIVE- IN ANCHORS. BOLT TENSION CAP CAN BE TURNED SO CABLES CAN RUN HORIZONTAL OR VERTICAL. FURNISHED FOR ALL AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A224 ALUMINUM ![]() 225 SIDE MOUNT BASE THIS CAST BASE CAN BE MOUNTED VERTICALLY WITH SCREWS, 1/4 " BOLTS, OR 1/4 " DRIVE- IN ANCHORS. BOLT TENSION CAP CAN BE TURNED SO CABLES CAN RUN HORIZONTAL OR VERTICAL. FURNISHED FOR ALL AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A225 ALUMINUM ![]() 227 TOP MOUNT BASE THIS CAST BASE HAS BOLT TENSION CABLE CLAMPING AND CAN BE MOUNTED HORIZONTALLY WITH SCREWS, 1/4" BOLTS, OR 1/4" DRIVE- IN ANCHORS. FURNISHED FOR ALL AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A227 ALUMINUM ![]() 228 NARROW SURFACE BASE THIS STRAP BASE CAN BE MOUNTED ON A NARROW SURFACE OR RIDGE ROOF WITH SCREWS OR NAILS. BASE CAN BE MODIFIED TO ACCEPT OTHER ANCHORS. COMPRESSION TYPE FINGERS CRIMP OVER CABLE FOR EASY INSTALLATION. AVAILABLE FOR CLASS I STRUCTURES ONLY. FURNISHED FOR AIR TERMINAL SIZES - 3/8" AND 1/2". SPECIFY WHEN ORDERING. A228 ALUMINUM ![]() 229 NARROW SURFACE BASE THIS STRAP BASE CAN BE MOUNTED ON A NARROW SURFACE OR RIDGE ROOF WITH SCREWS OR NAILS. BASE CAN BE MODIFIED TO ACCEPT OTHER ANCHORS. BOLT TENSION CAP PROVIDES MAXIMUM CABLE SUPPORT. FURNISHED FOR ALL AIR TERMINAL SIZES - 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A229 ALUMINUM ![]() 230 RIDGE MOUNT BASE THIS STRAP BASE CAN BE MOUNTED ON A RIDGE ROOF WITH SCREWS OR NAILS. BASE CAN BE MODIFIED TO ACCEPT OTHER ANCHORS. COMPRESSION TYPE FINGERS CRIMP OVER CABLE FOR EASY INSTALLATION. AVAILABLE FOR CLASS I STRUCTURES ONLY. FURNISHED FOR AIR TERMINAL SIZES - 3/8" AND 1/2". SPECIFY WHEN ORDERING. A230 ALUMINUM ![]() 231 RIDGE MOUNT BASE THIS STRAP BASE CAN BE MOUNTED ON RIDGE ROOF WITH SCREWS OR NAILS. BASE CAN BE MODIFIED TO ACCEPT OTHER ANCHORS. BOLT TENSION CAP PROVIDES MAXIMUM CABLE SUPPORT. FURNISHED FOR POINT SIZES - 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A231 ALUMINUM ![]() 231 TILE ROOF RIDGE BASE THIS STRAP BASE IS DESIGNED TO MOUNT OVER CLAY TILES WITHOUT SCREWS OR NAILS. BOLT TENSION CAP PROVIDES MAXIMUM CABLE SUPPORT. FURNISHED FOR AIR TERMINAL SIZES - 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A231TR ALUMINUM ![]() 232 CAST RIDGE BASE THIS CAST BASE CAN BE MOUNTED ON A RIDGE ROOF WITH SCREWS OR NAILS. CAST WITH A SOFT ALLOY SO IT CAN EASILY FORM TO THE RIDGE. THE BASE CAN BE MODIFIED TO ACCEPT OTHER ANCHORS. COMPRESSION TYPE FINGERS CRIMP OVER CABLE FOR EASY INSTALLATION. AVAILABLE FOR CLASS I STRUCTURES ONLY. FURNISHED FOR AIR TERMINAL SIZES - 3/8" AND 1/2". SPECIFY WHEN ORDERING. UL LISTED A232 ALUMINUM ![]() 233 CAST RIDGE BASE THIS CAST BASE CAN BE MOUNTED ON RIDGE ROOF WITH SCREWS OR NAILS. CAST WITH A SOFT ALLOY SO IT CAN EASILY FORM TO THE RIDGE. THIS BASE CAN BE MODIFIED TO ACCEPT OTHER ANCHORS. BOLT TENSION CAP PROVIDES MAXIMUM CABLE SUPPORT. FURNISHED FOR AIR TERMINAL SIZES - 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A233 ALUMINUM ![]() 235 CAST STRAIGHT BASE CAST STRAIGHT BASE. TWO SET SCREWS HOLD CABLE FIRMLY AND AIR TERMINAL SCREWS INTO TOP TO KEEP CABLE AND AIR TERMINAL IN STRAIGHT LINE. AVAILABLE FOR AIR TERMINAL SIZES 3/8" AND 1/2". SPECIFY WHEN ORDERING. UL LISTED A235 ALUMINUM ![]() 237 STANDING SEAM BASE THIS CAST BASE FOR STANDING SEAM ROOF HAS 3/4" GROOVE TO FIT OVER MOST SEAMS. PROVIDED WITH A SWIVEL ADAPTER FOR LEVELING AIR TERMINALS. CABLE HOLDER IS ADJUSTABLE SO CABLES CAN RUN PARALLEL OR PERPENDICULAR. TWO SET SCREWS SECURE BASE TO SEAM. AVAILABLE FOR AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A237 ALUMINUM ![]() 239 TOP MOUNT PIPE BASE THIS CAST PIPE BASE FOR USE WITH 0.750" TO 1.315 O.D. PIPE. THIS BASE CAN BE DRILLED FOR TOP MOUNT USE ONLY. AVAILABLE FOR AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A239 ALUMINUM
CAST PIPE BASES. BASE CAN BE DRILLED FOR TOP MOUNTING OR SIDE MOUNTING ON MOST PIPES. BASE SIZES RANGE FROM 1.314" TO 1.900" AND 1.750" TO 2.500". EACH BASE IS NUMBERED FOR EASY ORDERING. AVAILABLE FOR AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED TOP MOUNT BASE WITH 1.314" TO 1.900" RANGE A240 ALUMINUM SIDE MOUNT BASE WITH 1.314" TO 1.900" RANGE A241 ALUMINUM TOP MOUNT BASE WITH 1.750" TO 2.500" RANGE A242 ALUMINUM SIDE MOUNT BASE WITH 1.750" TO 2.500" RANGE A243 ALUMINUM ![]() STRAP BASES FORMED ALUMINUM OR COPPER TOP MOUNT PIPE BASES. ANY SIZE CAN BE FABRICATED TO ORDER. PLEASE USE 247X AND O.D. SIZE OF PIPE. EXAMPLES OF 11", 42", AND 48" O.D. PIPES ARE GIVEN. UL LISTED. TOP MOUNT BASE FOR PIPE SIZE 11" A247x11 - ALUMINUM TOP MOUNT BASE TOP MOUNT BASE FOR PIPE SIZE 42" A247x42 - ALUMINUM TOP MOUNT BASE TOP MOUNT BASE FOR PIPE SIZE 48" A247x48 - ALUMINUM TOP MOUNT BASE ![]() 250 STAMPED VENT BASE STAMPED VENT AIR TERMINAL BASE WITH NO CABLE HOLDER. OVER 8 SQUARE INCHES OF CONTACT TO DIRECT MOUNT AIR TERMINAL ON CONTINUOUS METAL SURFACE. FURNISHED FOR ALL AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A250 ALUMINUM 252 CAST AIR TERMINAL BASE CAST VENT AIR TERMINAL BASE WITH NO CABLE HOLDER. OVER 8 SQUARE INCHES OF CONTACT TO DIRECT MOUNT AIR TERMINAL ON CONTINUOUS METAL SURFACE. FURNISHED FOR ALL AIR TERMINAL SIZES 3/8", 1/2", AND 5/8". SPECIFY WHEN ORDERING. UL LISTED A252 ALUMINUM
Please |
|||